{"product_id":"temperature-and-humidity-control-module-digital-dual-output-automatic-high-precision-constant-temperature-humidity-control-board","title":"Temperature and Humidity Control Module Digital Dual Output Automatic High Precision Constant Temperature Humidity Control Board","description":"\u003ch1\u003eSPECIFICATIONS\u003c\/h1\u003e\u003cp\u003e\u003cspan\u003eBattery Included\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eNo\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eBrand Name\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eNONE\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eCertification\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eNone\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eHigh-concerned chemical\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eNone\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eOrigin\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eMainland China\u003c\/span\u003e\u003c\/p\u003e\u003cdiv class=\"detailmodule_html\"\u003e\u003cdiv class=\"detail-desc-decorate-richtext\"\u003e\n\u003cbr\u003e\u003cdiv\u003e\n\u003cbr\u003e\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:21px\"\u003eTemperature and Humidity Control Module Digital Dual Output Automatic High Precision Constant Temperature Humidity Control Board\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"color:rgb(255, 0, 0);font-size:19px\"\u003eSpecifications:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003eProduct model: XY-DTH1\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003eTemperature measurement range: -20°C~60°C\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003eHumidity range: 00%~100%RH\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003eControl accuracy: 0.1C 0.1%RH\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003eDetection probe: integrated sensorOutput type: relay output\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003eOutput capaity: maximum 10A\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003eProduct weight: 144g\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003eProduct functions are mainly classified into two categories: temperature function and humidity function;\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003eThe temperature function is as follows:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003e1.  Automatic recognition of working mode:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003eThe system automatically recognizes the working mode according to the start temperature\/stop temperature;\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003eStarting temperature\u0026gt;stop temperature, cooling mode ‘C’;  starting temperature;\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003e2.  Cooling mode:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003eWhen the detection temperature ≥ the starting temperature, the relay is turned on, the red indicator light is on, and the refrigeration equipment starts to work;\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003eWhen the detected temperature is less than or equal to the stop temperature, the relay is closed, the red indicator light is off, and the refrigeration equipment stops working;\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003e3.  Heating mode:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003eWhen the detection temperature is less than the start temperature, the relay is turned on, the red indicator light is on, and the heating device starts to work;\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003eWhen the detected temperature is greater than or equal to the stop temperature, the relay is closed, the red indicator light is off, and the heating device stops working;\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003e4.  Temperature correction function OFE (-10.0 ~ 10.0℃):\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003eThe system works for a long time, and there may be deviations.  Through this function, the actual temperature=measured temperature+calibration value;\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003eHow to set the start\/stop temperature:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003e1.  In the running interface, press and hold the ‘TM+’ key for more than 3 seconds to enter the startup temperature setting interface.  The test can be used to modify the parameters through the TM+ TM- keys.  After the parameter modification is completed, wait 6 seconds to automatically exit and save;\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003e2.  In the running interface, press and hold the ‘TM-’ key for more than 3 seconds to enter the stop temperature setting interface.  The test can be used to modify the parameters through the TM + TM- keys.  After the parameters are modified, wait for 6 seconds to automatically exit and save;\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003eHumidity functions are as follows:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003e1.  Automatic recognition of working mode:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003eThe system automatically recognizes the working mode according to the start humidity\/stop temperature;\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003eStart humidity\u0026gt; stop humidity, dehumidification mode ‘d’;  start humidity \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003e2.  Dehumidification mode:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003eWhen detecting humidity ≥ start humidity, the relay is turned on, the green indicator light is on, and the dehumidification equipment starts to work;\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003eWhen the detected humidity is less than or equal to the stop humidity, the relay is closed, the green indicator light is off, and the dehumidification equipment stops working;\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003e3.  Humidification mode:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003eWhen the detected humidity is less than the start humidity, the relay is turned on, the green indicator light is on, and the humidifying device starts to work;\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003eWhen detecting humidity ≥ stop humidity, the relay is turned off, the green indicator light is off, and the humidifying device stops working\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003e4.  Humidity correction function RH (-10.0 ~ 10.0℃):\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003eThe system works for a long time, and there may be deviations.  Through this function, the actual humidity = measured humidity + calibration value;\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003eHow to set start\/stop humidity:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003e1.  In the running interface, press and hold the ‘RH+’ key for more than 3 seconds to enter the start humidity setting interface.  The test can be used to modify the parameters through the RH+ RH- key.  After the parameters are modified, wait for 6 seconds to automatically exit and save;\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003e2.  In the running interface, press and hold the ‘RH-’ key for more than 3 seconds to enter the stop humidity setting interface.  The test can be used to modify the parameters through the RH+ RH- key.  After the parameters are modified, wait for 6 seconds to automatically exit and save;\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003eOperation interface description:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003eWorking mode display.  After the start temperature\/humidity, stop temperature\/humidity and other parameters are set, the current mode (\"H\/C\", \"E\/d\") will be displayed in front of the temperature\/humidity;\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003eWhen any relay is turned on, the upper left corner of the interface displays \"OUT\".  If the temperature relay is turned on, the temperature operating mode \"H\/C\" flashes to indicate a reminder;  if the humidity relay is turned on, the humidity operating mode \"E\" flashes \/d\", as a reminder;\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"color:rgb(255, 0, 0);font-size:19px\"\u003eOther functions:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003e1.  Remote reading\/setting of parameters:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003eYou can set parameters such as start temperature\/humidity, stop temperature\/humidity, and temperature\/humidity correction through UART;\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003e2.  Real-time reporting of temperature\/humidity:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003eIf the temperature\/humidity report function is turned on, the product will detect the temperature\/humidity and relay status at 1s intervals and transmit it to the terminal via UART, which is convenient for data collection;\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003e3. Relay enable (open by default):\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003eIf the relay enable is turned off, the relay remains off;\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003eHow to modify the temperature\/humidity correction value:\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003e1. In the running interface, double-click the ‘TM+’ key to enter the correction value setting interface; the lower line displays the correction value type, and the upper line displays the specific value; (OFE: temperature correction value RH: humidity correction value)\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003e2. At this time, short press the ‘TM-’ key to switch the parameter to be modified, and use the RH+ RH- key to modify the specific value; long-press and short-press are supported;\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003e3. After the parameter modification is completed, double-click the ‘TM+’ key to exit the correction value setting interface and save the data;\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003eHow to turn on\/off the relay enable switch:\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003eIn the running interface, short press the'TM-' key to turn on or off the temperature relay enable (on: turn on OFF: turn off). After returning to the running interface, if the temperature relay is off, the temperature symbol'℃' will flash, Reminder.\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003eIn the running interface, short press the'RH-' key to turn on or off the humidity relay enable (on: open OFF: close). After returning to the running interface, if the humidity relay is in the off state, the humidity symbol'%' will flash, Reminder.\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"white-space:normal\"\u003e\u003cspan\u003e\u003cspan style=\"color:rgb(255, 0, 0);font-size:19px\"\u003eNote: \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"white-space:normal\"\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003e1.Due to the light and screen difference, the item's color may be slightly different from the pictures.\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"white-space:normal\"\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003e2.Please allow 1-3cm differences due to manual measurement.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"white-space:normal\"\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"white-space:normal\"\u003e\u003cspan\u003e\u003cspan style=\"color:rgb(255, 0, 0);font-size:19px\"\u003ePackage Included:\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"white-space:normal\"\u003e\u003cspan\u003e\u003cspan style=\"font-size:19px\"\u003e1x Temperature and Humidity Control Module\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg style=\"max-width:100%\" src=\"https:\/\/ae01.alicdn.com\/kf\/S6c2bcbf2159f45c393afaa672b4e405aK.jpg\" slate-data-type=\"image\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg style=\"max-width:100%\" src=\"https:\/\/ae01.alicdn.com\/kf\/Sc2bb6445dd504d3084edcc4705c24836w.jpg\" slate-data-type=\"image\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg style=\"max-width:100%\" src=\"https:\/\/ae01.alicdn.com\/kf\/S9c496a39b5194e34992809f39ac1e008p.jpg\" slate-data-type=\"image\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg style=\"max-width:100%\" src=\"https:\/\/ae01.alicdn.com\/kf\/Sba9eb9fbfad34d549e8b4ee30310c67dz.jpg\" slate-data-type=\"image\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg style=\"max-width:100%\" src=\"https:\/\/ae01.alicdn.com\/kf\/S5f8d07c23d8c44d5ba13c9e4fd0b2313R.jpg\" slate-data-type=\"image\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg style=\"max-width:100%\" src=\"https:\/\/ae01.alicdn.com\/kf\/Sb9439f4f1e95423ebf186d9610f06053i.jpg\" slate-data-type=\"image\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg style=\"max-width:100%\" src=\"https:\/\/ae01.alicdn.com\/kf\/S4bc787a7780e4111ab65d130d2a2a4eeD.jpg\" slate-data-type=\"image\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg style=\"max-width:100%\" src=\"https:\/\/ae01.alicdn.com\/kf\/Se1bba0a8c7df4e2d98828a2d6ca39006Y.jpg\" slate-data-type=\"image\"\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003cbr\u003e","brand":"PDG ibma","offers":[{"title":"Default Title","offer_id":52954944831851,"sku":"\u003cnone\u003e","price":9946.0,"currency_code":"XOF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0933\/1638\/3083\/files\/Sc2bb6445dd504d3084edcc4705c24836w.webp?v=1775573650","url":"https:\/\/jznpjn-rq.myshopify.com\/products\/temperature-and-humidity-control-module-digital-dual-output-automatic-high-precision-constant-temperature-humidity-control-board","provider":"PDG ibma","version":"1.0","type":"link"}